4 Conformance
For a cabling system to conform to this document the following applies.
a) The configuration and structure shall conform to the requirements outlined in Clause 5.
b) Channels shall meet the requirements specified in Clause 6 when subjected to environment conditions, local to the channels (see NOTE below), as defined by the applicable environmental Class(es) of Clause 6.
This shall be achieved by one of the following:
1 ) a channel design and implementation ensuring that the prescribed channel performance of Clause 6 is met;
2) attachment of appropriate components to a permanent link or service concentration point (SCP) link design meeting the prescribed performance class of Clause 7.
Channel performance shall be ensured where a channel is created by adding more than one cord to either end of a link meeting the requirements of Clause 7;
3) for E 1 environments, using the reference implementations of Clause 8 and compatible cabling components conforming to the requirements of Clauses 9, 1 0 and 1 1 , this is based upon a statistical approach of performance modelling.
c) The interfaces to the cabling at the SO shall conform to the requirements of Clause 1 0 with respect to mating interfaces and performance when subjected to environment conditions, local to the connecting hardware (see NOTE below), as defined by the applicable environmental Class(es) of Clause 6.
d) Connecting hardware at other places in the cabling structure shall meet the performance requirements specified in Clause 1 0 when subjected to environment conditions, local to the connecting hardware (see NOTE below), as defined by the applicable environmental
Class(es) of Clause 6
e) The requirements of ISO/IEC 1 4763-2 and ISO/IEC 301 29 shall be met.
This document does not specify which tests and sampling levels should be adopted. Test methods to assess conformance with the channel and link requirements of Clause 6 and Clause 7, respectively, are specified in ISO/IEC 1 1 801 -1 . The test parameters to be measured, the sampling levels and the treatment of measured results to be applied for particular installations shall be defined in the installation specifications and quality plan for that installation prepared in accordance with ISO/IEC 1 4763-2.