AS CA S043.1:2015 Requirements for Customer Equipment for connection to a metallic local loop interface of a Telecommunications Network

AS CA S043.1:2015 Requirements for Customer Equipment for connection to a metallic local loop interface of a Telecommunications Network
5.1.1 General
CE that is capable of voice communication or TTY communication in accordance with ITU-T Recommendation V.18 [3] is to comply with the following requirements:
(a) CE with a dialling capability and used for voice communication shall support the dialing of emergency service number‘000′.
(b) CE with a handset and with a dialing capability shall support the dialing of emergency service numbers‘000′ and“106′.
(c) (C)TTY terminals or CE with equivalent functionality that can be connected to the Telecommunications Network shall support the dialling of emergency service number“106′.Compliance with Clause 5.1.1 may be checked by operation and inspection.
5.1.2 Access barring
CE should not support access barring of emergency service numbers ‘000′ and“106′.
5.1.3 Loss of mains power
Mains- powered CE should continue to support the dialling of emergency service numbers for at least 30 minutes following the loss
of mains power.
5.1.4 Provision of power-fail advice
CE that does not continue to support emergency dialling for at least 30 minutes after loss of mains power shall have an appropriately worded warning notice included in or with the CE documentation. The warning notice should also be placed on the outside surface of the CE’s packaging. A suggested wording for the warning notice is as follows:
5.2.1 Operation
The operation of CE should be independent of:
(a) line conductor polarisation, i.e. the connection of specific conductors of the line pairs to specific line terminals of the CE;and
(b) the polarity of any voltage on any specific line conductor.
5.2.2 Line polarity reversal
Normal operation of CE should be independent of, and should remain unaffected by, any reversal (momentary of otherwise) in line
polarity.
5.3 Line connection
CE should terminate on and be supplied with:
(a) an insulation displacement connection system;
(b) a cable complying with AS/CA S008 [2] and which is able to be terminated on an insulation displacement connection system;
(c) a socket on the CE complying with AS/CA S008 [2]; or
(d) a modular 8-way plug on the end of a line cord, where both the plug and cord comply with the requirements of AS/CA S008 [2] and the plug is Plug Type FCC 68 [4] (eight-position).
Note: The following pin assignments should be used where a Plug Type FCC 68 [4] (eight-position) is supplied for connection of CE.